ITV164 FAQ

Water inlet leakage

Possible Causes:

  • Filter missing or not installed properly.

  • The faucet is not the standard 3/4".

Solutions:

  • Add a filter and make sure it's placed horizontally in the inlet.

  • Make sure the faucet is a standard 3/4" faucet.

  • Wrap Teflon tape on the tap making it tight.

Water does not stop flowing

Possible Causes:

  • Long-term storage or transportation may cause the valve to become inactive.

  • Valve blockage.

Solutions:

  • Keep the tap turned off and turn the timer dial to ON.

  • Run the manual watering for 5–7 seconds and stop it.

  • Repeat step 2 for 3 to 5 times.

  • Resume normal operation.

No response for manual/rain delay function

Possible Causes:

  • After setting manual watering or rain delay time, without pressing OK button to save and run.

Solutions:

  • Press OK button again after the time is set to confirm.

 

Low water pressure

Possible Causes:

  • Filter blockage.

  • Inlet pressure not sufficient to support watering needs.

Solutions:

  • Check if the filter is clogged; if so, clean or replace the filter.

  • Make sure the timer is installed properly and not cross-threaded.

  • Install a booster pump or other auxiliary equipment for increasing pressure.

LCD screen does not display

Possible Causes:

  • The battery power is too low.

  • The solar panel is covered, blocked, or shaded.

Solutions:

  • Place the solar panel in direct sunlight to charge the timer.

  • Make sure the solar panel is clean and not covered, blocked, or shaded.

  • Wait until sufficient power is restored, then check the LCD screen again.